變(bian)壓器繞組變(bian)形測試(shi)儀具有頻(pin)率(lv)響應(ying)法和(he)短(duan)路(lu)阻抗(kang)法兩(liang)種(zhong)測(ce)試(shi)方(fang)法(fa),用(yong)兩(liang)種(zhong)不(bu)同(tong)的(de)方(fang)法(fa)對電力變(bian)壓器繞組進(jin)行測(ce)量,全(quan)面反(fan)映(ying)變(bian)壓器的繞組特(te)性(xing),更(geng)加(jia)準(zhun)確地(di)分析(xi)、診斷(duan)繞組變(bian)形情況(kuang)。頻(pin)響法和(he)阻抗(kang)法兩(liang)種(zhong)設(she)備合成(cheng),節省(sheng)測(ce)試(shi)時間,提(ti)高(gao)工作效(xiao)率。儀(yi)器短(duan)路阻抗(kang)測試(shi)法,又(you)分為(wei)內部(bu)輸(shu)出(chu)模(mo)式(shi)的(de)低(di)電(dian)壓短路(lu)阻抗(kang)法和(he)外(wai)部輸(shu)入電源(yuan)模(mo)式(shi)的(de)短(duan)路阻抗(kang)法。
變(bian)壓器繞組變(bian)形測試(shi)儀(頻(pin)率響應(ying)法)用(yong)於(yu)測(ce)試(shi)6kV及(ji)以(yi)上電壓(ya)等(deng)級電(dian)力變(bian)壓器及(ji)其(qi)它特殊(shu)用(yong)途(tu)的(de)變(bian)壓器,運行或(huo)運輸(shu)過程(cheng)中(zhong)不可(ke)避(bi)免(mian)地(di)要(yao)遭受(shou)各種(zhong)故障短路(lu)電(dian)流的沖(chong)擊或(huo)者物理(li)撞(zhuang)擊。在(zai)短路(lu)電(dian)流(liu)產生的(de)強大電(dian)動(dong)力作用(yong)下(xia),變(bian)壓器繞組可(ke)能(neng)失去穩(wen)定性(xing),導致(zhi)局部(bu)扭(niu)曲(qu)、鼓包或(huo)移位(wei)等變(bian)形現象,這(zhe)樣將嚴重影(ying)響變(bian)壓器的安(an)全(quan)運行。本(ben)儀器按國家電(dian)力行業(ye)標準(zhun)DL/T911-2016、國際(ji)電(dian)工標準(zhun)IEC60076-18采用(yong)頻(pin)率(lv)響應(ying)分析(xi)法測(ce)量變(bian)壓器的繞組變(bian)形,是通(tong)過檢(jian)測變(bian)壓器各個繞(rao)組的(de)幅(fu)頻(pin)響應(ying)特性(xing),並對檢(jian)測結(jie)果進(jin)行縱(zong)向或(huo)橫向比(bi)較,根據幅(fu)頻(pin)響應(ying)特性(xing)的變(bian)化程(cheng)度(du),判斷(duan)變(bian)壓器繞組可(ke)能(neng)發(fa)生的(de)變(bian)形情況(kuang)。
變(bian)壓器繞組變(bian)形測試(shi)儀(阻抗(kang)法)專(zhuan)門用(yong)於(yu)測(ce)量大中(zhong)型變(bian)壓器阻抗(kang)特性(xing)測試(shi)的智(zhi)能化儀器(qi)。國家電(dian)力公司頒發(fa)的(de)[2000] 589 號(hao)文件《防(fang)止電(dian)力生產(chan)重大(da)事(shi)故的(de)二十(shi)五(wu)項重點(dian)要(yao)求》中(zhong)15.2條規定:“110KV及(ji)以(yi)上電壓(ya)等(deng)級變(bian)壓器在(zai)出廠(chang)和(he)投(tou)產(chan)前應(ying)做(zuo)低(di)電(dian)壓短路(lu)阻抗(kang)測試(shi)或(huo)用(yong)頻(pin)響法測(ce)試(shi)繞組變(bian)形以保留原(yuan)始(shi)記錄。"15.6 中(zhong)規定:“變(bian)壓器在(zai)遭受(shou)近(jin)區(qu)突(tu)發(fa)短路後,應(ying)做(zuo)低(di)電(dian)壓短路(lu)阻抗(kang)測試(shi)或(huo)用(yong)頻(pin)響法測(ce)試(shi)繞組變(bian)形,並與原(yuan)始(shi)記錄比(bi)較,判斷(duan)變(bian)壓器後,方(fang)可(ke)投(tou)運。"低(di)電(dian)壓短路(lu)阻抗(kang)測試(shi)能準(zhun)確反(fan)應(ying)變(bian)壓器在(zai)繞組變(bian)形前後阻抗(kang)值的(de)變(bian)化。測試(shi)儀器(qi)內部(bu)采用(yong)電(dian)壓(ya)、電流高(gao)精(jing)度同(tong)步(bu)交(jiao)流(liu)采樣(yang)及(ji)FFT等(deng)數字(zi)信(xin)號(hao)處(chu)理(li)技(ji)術(shu),測量數據準(zhun)確、穩(wen)定。該(gai)儀(yi)器采用(yong)三相自動(dong)測(ce)量或(huo)者單(dan)相測量方(fang)式(shi),將低(di)壓(ya)側(ce)可(ke)靠短(duan)接(jie),輸(shu)入變(bian)壓器參數後,儀器(qi)便(bian)可(ke)自(zi)動(dong)測(ce)試(shi)、自動(dong)計算各(ge)相阻抗(kang)及(ji)阻抗(kang)誤(wu)差百分比(bi),測試(shi)結果(guo)非常(chang)直觀。測試(shi)過程(cheng)中(zhong)顯示電(dian)壓(ya)電(dian)流波(bo)形,更(geng)加(jia)適合現場(chang)使(shi)用(yong)。
上壹篇(pian):變(bian)壓器短路阻抗(kang)測試(shi)儀測(ce)試(shi)方(fang)法(fa)
下(xia)壹(yi)篇(pian):變(bian)壓器繞組變(bian)形測試(shi)儀頻(pin)率響應(ying)法主(zhu)要(yao)特點(dian)
電(dian)話(hua)
微(wei)信(xin)掃壹(yi)掃